APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V, (21) C13 & (3) C19

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V, (21) C13 & (3) C19

Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V, (21) C13 & (3) C19

Trade Prices

Distributor Product SKU Stock Updated Price
CMS Distribution (Ireland) PDU 2G Metered-by-Outlet 16A 230V 000000000000242227 Register free see stock
Exertis IT Rack PDU 2G Metered-by-Outlet ZeroU 16A 230V (21) C13 & (3) C19 10037131
Ingram Micro RACK PDU 2G METERED-BY-OUTLET 270B128
Microwarehouse Ireland Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V, (21) C13 & (3) C19 AP8459EU3
TD Synnex UK APC Metered-by-Outlet Rack PDU 2G - Power distribution unit (rack-mountable) - AC 200/208/230 V - Ethernet - input: IEC 60309 - output connectors: 24 - 0U - black - for P/N: SMX1500RMNCUS, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10RMXLIX806, SRT5KRMXLW-TW 3240539
Westcoast/Data Select RACK PDU 2G METERED-BY-OUTLET ZEROU AP8459EU3
ECPROF Metered-by-Outlet Rack PDU 2G - Stromverteilungseinheit (Rack - einbauf+?-?hig) AP8459EU3
EET Rack PDU 2G Metered-by-Outlet AP8459EU3
Ingram Micro CS RACK PDU 2G METERED-BY-OUTLET 270B128
Memory Bank RACK PDU 2G METERED-BY-OUTLET ZEROU CLAP8459EU3
SYNAXON Metered-by-Outlet Rack PDU 2G - power distribution unit STD10123826

Retail Prices

Merchant Product Condition Updated Price
Amazon New £1,021.00
Amazon Used £976.00

Description

APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection Current metering provides real-time remote monitoring of connected loads Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency

Specifications

Design
PDU typesMetered, Metered-by-outlet
MountingVertical
Product colourBlack
CertificationEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A, VDE REACH
Rack capacity0U
Ports & interfaces
AC outlets quantity24 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Output connections21 x C13 & 3 x C19
Features
Cable length3 m
LED indicatorsYes
CertificationEN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A, VDE REACH
Management features
MonitoringCurrent, Power, Voltage
Ergonomics
Cable length3 m
LED indicatorsYes
Power
Maximum power3680 W
Nominal input voltage200-230 V
Nominal output voltage230 V
Maximum current16 A
Maximum total current draw per phase16 A
Maximum input current per phase16 A
Load capacity3680 VA
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)56 x 51 x 1829 mm
Weight6.76 kg
Package weight9.03 kg
Package dimensions (WxDxH)163 x 117 x 2037 mm
Packaging data
Package weight9.03 kg
Package dimensions (WxDxH)163 x 117 x 2037 mm
Operational conditions
Operating temperature (T-T)-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 3000 m
Non-operating altitude0 - 15000 m
Technical details
Compliance certificatesRoHS